← Back to catalog

Ivanti · Sentry

CVE-2026-10520

Ivanti Sentry OS Command Injection Vulnerability

CISA KEV record

CISA date added
2026-06-11
CISA due date
2026-06-14
Known ransomware use
Unknown

NVD risk context

10.0 CRITICAL

CVSS is a technical severity score. CISA’s KEV status remains the evidence that this vulnerability is known to be exploited.

View NVD record ↗
Attack vector
Network
The vulnerable service can be reached remotely over a network.
Attack complexity
Low
Exploitation does not require unusual conditions beyond normal attacker control.
Privileges required
None
The attacker does not need an existing account or privileges.
User interaction
None
No action by another user is required.

Description

Ivanti Sentry (formerly known as MobileIron Sentry) contains an OS command injection vulnerability which could allow a remote unauthenticated user to achieve root-level remote code execution. This vulnerability can be successfully exploited in cases where the Sentry appliance is in an unmanaged state with its endpoints externally reachable. The use of mTLS with EPMM or restricted HTTPS access through Neurons for MDM makes interfaces inaccessible to external actors.

Required action

Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.

NVD reference index

Vendor and remediation references

NVD has tagged these sources as vendor advisories, patches, mitigations, or release notes.

Other NVD references (2)

MITRE CWE context

CWE classification

CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')

The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component.

View official MITRE CWE details ↗

NVD record timing

NVD record timeline

These dates describe NVD’s record, not CISA’s KEV addition or remediation due date.

NVD published
Jun 09, 2026, 04:16 PM UTC
When NVD first published this CVE record.
NVD last updated
Jul 23, 2026, 08:10 AM UTC
When NVD last changed its analysis or record data.
Advanced: view the technical CVSS vector

This standardized code is intended for security tools and technical analysts. The plain-language risk summary above explains its main points.

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H

View NVD record ↗

CISA notes

https://hub.ivanti.com/s/article/Security-Advisory-Ivanti-Sentry-CVE-2026-10520-CVE-2026-10523?language=en_US ; BOD 26-04: https://www.cisa.gov/news-events/directives/bod-26-04-prioritizing-security-updates-based-risk ; Forensics Triage Requirements: https://www.cisa.gov/news-events/directives/bod-26-04-implementation-guidance-prioritizing-security-updates-based-risk ; https://nvd.nist.gov/vuln/detail/CVE-2026-10520