← Back to catalog

NextGen Healthcare · Mirth Connect

CVE-2023-43208

NextGen Healthcare Mirth Connect Deserialization of Untrusted Data Vulnerability

CISA KEV record

CISA date added
2024-05-20
CISA due date
2024-06-10
Known ransomware use
Known

NVD risk context

9.8 CRITICAL

CVSS is a technical severity score. CISA’s KEV status remains the evidence that this vulnerability is known to be exploited.

View NVD record ↗
Attack vector
Network
The vulnerable service can be reached remotely over a network.
Attack complexity
Low
Exploitation does not require unusual conditions beyond normal attacker control.
Privileges required
None
The attacker does not need an existing account or privileges.
User interaction
None
No action by another user is required.

Description

NextGen Healthcare Mirth Connect contains a deserialization of untrusted data vulnerability that allows for unauthenticated remote code execution via a specially crafted request.

Required action

Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.

NVD reference index

Vendor and remediation references

NVD has not tagged a reference for this KEV as a patch, mitigation, release note, or vendor advisory.

Other NVD references (3)

MITRE CWE context

CWE classification

CWE-502 Deserialization of Untrusted Data

The product deserializes untrusted data without sufficiently ensuring that the resulting data will be valid.

View official MITRE CWE details ↗

NVD record timing

NVD record timeline

These dates describe NVD’s record, not CISA’s KEV addition or remediation due date.

NVD published
Oct 26, 2023, 05:15 PM UTC
When NVD first published this CVE record.
NVD last updated
Jun 17, 2026, 06:25 AM UTC
When NVD last changed its analysis or record data.
Advanced: view the technical CVSS vector

This standardized code is intended for security tools and technical analysts. The plain-language risk summary above explains its main points.

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

View NVD record ↗

CISA notes

This vulnerability affects a common open-source component, third-party library, or a protocol used by different products. Please check with specific vendors for information on patching status. For more information, please see: https://github.com/nextgenhealthcare/connect/wiki/4.4.1---What%27s-New ; https://nvd.nist.gov/vuln/detail/CVE-2023-43208